Gauss

  • Brasil
  • Global
  • América Latina

Voltage Regulator - GA140

Brief Specifications

ID
-
Field
NEGATIVE B
Voltage
14
Technology
CONVENTIONAL
Set Point (V)
14.5
Related Image
38670
Alternator Code
DENSO: 104210-329, 104210-473, 104210-5370, 104210-3290, 104210-3291, 104210-3292, 104210-3293, 104210-4730, 104210-4731, 104210-4732, 104210-5310, 104210-5378 HONDA: 31100-RAA-A01, 31100-RAA-A03, 31100-RAA-A04, 31100-RAA-A05, 31100-RTA-003, 31100-RTA-013, 31100-RTA-023
Test Observations
Regulators with "DFM", "FR", "LI" terminal - regulator pulse output terminal to the vehicle's Electronic Control Unit to inform about the regulator’s functioning. To check its operation, use the sensors test module in the Frequency function. Using the PU02 cable set, connect the green tip to the "IN" input and the red tip to the "+ 5V REF" input, then connect the green alligator clip to the DFM, FR or LI terminal attached with the red alligator clip (+ 5V REF). Perform the regulator test and, during the test, the DFM (FR, LI) signal output frequency and the percentage of the time that the signal remains high should appear on the LCD screen of the sensors test module.

Brief Application

Brand
Model
HONDA
ACCORD IX Saloon (CR)
HONDA
ACCORD V (CE, CF_, CD)
HONDA
ACCORD VI (CK, CG, CH, CF, CL)
HONDA
ACCORD VI Hatchback (CH, CL)
HONDA
ACCORD VII (CL, CN)
HONDA
ACCORD VII (CM)
HONDA
ACCORD VIII (CP)
HONDA
ACCORD VIII (CU)
HONDA
ACCORD X Saloon (CV)
HONDA
CIVIC IX Coupe
ID
-
Field
NEGATIVE B
Voltage
14
Technology
CONVENTIONAL
Set Point (V)
14.5
Related Image
38670
Alternator Code
DENSO: 104210-329, 104210-473, 104210-5370, 104210-3290, 104210-3291, 104210-3292, 104210-3293, 104210-4730, 104210-4731, 104210-4732, 104210-5310, 104210-5378 HONDA: 31100-RAA-A01, 31100-RAA-A03, 31100-RAA-A04, 31100-RAA-A05, 31100-RTA-003, 31100-RTA-013, 31100-RTA-023
Test Observations
Regulators with "DFM", "FR", "LI" terminal - regulator pulse output terminal to the vehicle's Electronic Control Unit to inform about the regulator’s functioning. To check its operation, use the sensors test module in the Frequency function. Using the PU02 cable set, connect the green tip to the "IN" input and the red tip to the "+ 5V REF" input, then connect the green alligator clip to the DFM, FR or LI terminal attached with the red alligator clip (+ 5V REF). Perform the regulator test and, during the test, the DFM (FR, LI) signal output frequency and the percentage of the time that the signal remains high should appear on the LCD screen of the sensors test module.
See more

Related
products

See all products
See all products

Compare and find the
ideal product for you!

No se seleccionó ningún producto.
Continúe navegando y seleccione productos para compararlos.
Our launches

See our
new releases

See the products
Our Catalog

Download our
product catalogue

Download catalogue
Chamar pelo WhatsApp